4000 - DETECTORs - MATRIX Systems (Series 4000)
4200 - MATRIX Systems for LARGE Beams Mapping
show product details hide product details PRELIMINARY  MR 4201 DD - 1D-MATRIX – LINEAR pattern – 220 DIODEs
» for High-resolution measurements of Beam Profiles
1D-MATRIX – LINEAR pattern – 220 DIODEs
Avanced tool for QC testing of radiation fields. It allows to measure profile both for open and for wedged fields very quickly and comfortably.
 
MEASURED AND EVALUATED PARAMETERS :
- Beam profile
- Light and radiation profiles coincidence
 
DETECTORs :
- 220 Diode Detectors (DD) - active area  0.5 x 0.5 mm
   Detector spacing is 2 mm
   Max. profile lenght 44 cm
- Beams:  photons 1-25MV  /  electrons 4-25MeV
 
DESIGN :
- LINEAR pattern
- Dimensions / Weight:  450x15x15mm  / 0.5kg
 
UNBEATABLE  POWER / PRICE  RATIO
show product details hide product details PRELIMINARY  MR 4201 IC - 1D-MATRIX – LINEAR pattern – 176 ION.CHAMBERs
» for High-resolution measurements of Beam Profiles
1D-MATRIX – LINEAR pattern – 176 ION.CHAMBERs
Avanced tool for QC testing of radiation fields. It allows to measure profile both for open and for wedged fields very quickly and comfortably.
 
MEASURED AND EVALUATED PARAMETERS :
- Beam profile
 
DETECTORs :
- 176 Ionization Chambers (IC) - active area  2 x 4 mm
   Detector spacing is 2.5 mm
   Max. profile lenght 44 cm
- Beams:  photons 1-25MV  /  electrons 4-25MeV
 
DESIGN :
- LINEAR pattern
- Dimensions / Weight:  450x15x15mm  / 0.5kg
 
UNBEATABLE  POWER / PRICE  RATIO
show product details hide product details COMING SOON      MR 4234 IC - 2D-MATRIX – GRID pattern – 2300 ION.CHAMBERs
» for IMRT verification and QC testing of Beams used in Radiotherapy
2D-MATRIX – GRID pattern – 2300 ION.CHAMBERs
Multipurpose tool for IMRT verification and for QC testing of large / medium size radiation fields used for radiotherapy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
 
MEASURED AND EVALUATED PARAMETERS :
- IMRT patient treatment plans verification
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
 
DETECTORs :
- 2298 Ionization Chambers (IC) - diameter 4 mm
- Beams:  photons 1-25MV  /  electrons 4-25MeV
- Dose Rate Range:  0.1÷50 Gy/min  (resol. 0.1%)
 
DESIGN :
- GRID pattern with spacing 10 mm  /  in HD area 7 mm
- Tested Field Sizes:  max. 35x40 cm
- High density (HD) area :  30x34 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight:  370x530x38 mm  / 8kg
 
UNBEATABLE  POWER / PRICE  RATIO