Avanced tool for QC testing of radiation fields. It allows to measure profile both for open and for wedged fields very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Beam profile
- Light and radiation profiles coincidence
DETECTORs :
- 220 Diode Detectors (DD) - active area 0.5 x 0.5 mm
Detector spacing is 2 mm
Max. profile lenght 44 cm
- Beams: photons 1-25MV / electrons 4-25MeV
DESIGN :
- LINEAR pattern
- Dimensions / Weight: 450x15x15mm / 0.5kg
UNBEATABLE POWER / PRICE RATIO
|
4000 - DETECTORs - MATRIX Systems (Series 4000)
4200 - MATRIX Systems for LARGE Beams Mapping
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
» for High-resolution measurements of Beam Profiles
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
» for High-resolution measurements of Beam Profiles
![]() |
Avanced tool for QC testing of radiation fields. It allows to measure profile both for open and for wedged fields very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Beam profile
DETECTORs :
- 176 Ionization Chambers (IC) - active area 2 x 4 mm
Detector spacing is 2.5 mm
Max. profile lenght 44 cm
- Beams: photons 1-25MV / electrons 4-25MeV
DESIGN :
- LINEAR pattern
- Dimensions / Weight: 450x15x15mm / 0.5kg
UNBEATABLE POWER / PRICE RATIO
|
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-VD.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for IMRT verification and QC testing of Beams used in Radiotherapy
![]() |
Multipurpose tool for IMRT verification and for QC testing of large / medium size radiation fields used for radiotherapy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- IMRT patient treatment plans verification
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
DETECTORs :
- 2298 Ionization Chambers (IC) - diameter 4 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.1÷50 Gy/min (resol. 0.1%)
DESIGN :
- GRID pattern with spacing 10 mm / in HD area 7 mm
- Tested Field Sizes: max. 35x40 cm
- High density (HD) area : 30x34 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 370x530x38 mm / 8kg
UNBEATABLE POWER / PRICE RATIO
|
4300 - MATRIX Systems for MEDIUM Beams Mapping
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for Daily QC Checks of Beams used in Radiotherapy
![]() |
Multipurpose tool for QC testing of radiation fields. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
- Light and radiation fields coincidence
DETECTORs :
- 241 Diode Detectors (DD) - active area 0.5 x 0.5 mm
- 13 Ionization Chambers (IC)
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.01÷30 Gy/min (resol. 0.1%)
DESIGN :
- STAR pattern:
61 DDs in each profile with spacing 2.5 / 5 mm
7 DDs in each field penumbra (w. spacing 2.5)
12 ICs for beam energy stability check
1 IC at CAX for beam output stability check
- Tested Field Sizes: 5x5 / 10x10 / 15x15 /20x20 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 250x300x15mm / 1.5kg
UNBEATABLE POWER / PRICE RATIO
|
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for Daily QC Checks of Beams used in Radiotherapy
![]() |
Multipurpose tool for QC testing of radiation fields. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
DETECTORs :
- 512 Ionization Chambers (IC) - rounded 2x4 mm
- 13 Ionization Chambers (IC) - diameter 3 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.1÷30 Gy/min (resol. 0.1%)
DESIGN :
- STAR pattern:
91 ICs in each CAX profile with spacing 2.5
21 ICs in each Off-CAX profile with spacing 2.5 / 5 mm
7 ICs in each field penumbra (w. spacing 2.5)
12 ICs for beam energy stability check
1 IC at CAX for beam output stability check
- Tested Field Sizes: 5x5 / 10x10 / 15x15 /20x20 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 300x500x15mm / 1.5kg
UNBEATABLE POWER / PRICE RATIO
|
4400 - MATRIX Systems for SMALL Beams Mapping
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-VD.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for IMRT verification and QC testing of Beams used in Stereotactic Radiotherapy
![]() |
Multipurpose tool for IMRT verification and for QC testing of small radiation fields used for stereotaxy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- IMRT patient treatment plans verification
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
DETECTORs :
- 640 Diode Detectors (DD) - active area 0.5 x 0.5 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.01÷30 Gy/min (resol. 0.1%)
DESIGN :
- GRID pattern with spacing 4 mm
- Tested Field Sizes: max. 10x10 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 150x250x15mm / 1kg
UNBEATABLE POWER / PRICE RATIO
|
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-VD.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for IMRT verification and QC testing of Beams used in Stereotactic Radiotherapy
![]() |
Multipurpose tool for IMRT verification and for QC testing of small radiation fields used for stereotaxy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- IMRT patient treatment plans verification
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
DETECTORs :
- 640 Ionization Chambers (IC) - diameter 2 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.1÷30 Gy/min (resol. 0.1%)
DESIGN :
- GRID pattern with spacing 4 mm
- Tested Field Sizes: max. 10x10 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 150x250x15mm / 1kg
UNBEATABLE POWER / PRICE RATIO
|
4500 - MATRIX Systems for PENCIL Beams Mapping
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for QC Tests of Very Small Radiation Fields (Pencil beams)
![]() |
Multipurpose tool for QC testing of radiation fields used for stereotaxy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
- Light and radiation fields coincidence
DETECTORs :
- 64 Diode Detectors (DD) - active area 0.5 x 0.5 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.01÷30 Gy/min (resol. 0.1%)
DESIGN :
- GRID pattern with spacing 1.5 mm
- Tested Field Sizes: Circular - max. 2 cm
- Dimensions / Weight: 40x130x6 mm / 0.1kg
UNBEATABLE POWER / PRICE RATIO
|
![show product details](/www/img/icons/toggle-show.png)
![hide product details](/www/img/icons/toggle-hide.png)
![](http://minirad.cz/www/img/ico_labels/R-VD.png)
![](http://minirad.cz/www/img/ico_labels/R-RD.png)
![](http://minirad.cz/www/img/ico_labels/R-AD.png)
» for QC Tests of Very Small Radiaton Fields (Pencil beams)
![]() |
Multipurpose tool for QC testing of radiation fields used for stereotaxy. It allows to measure all standard quality assurance parameters very quickly and comfortably.
MEASURED AND EVALUATED PARAMETERS :
- Absolute dose at CAX
- Beam energy stability
- Relative dose analyzes - symmetry, flatness
- Light and radiation fields coincidence
DETECTORs :
- 64 Ionization Chambers (IC) - diameter 2 mm
- Beams: photons 1-25MV / electrons 4-25MeV
- Dose Rate Range: 0.1÷30 Gy/min (resol. 0.1%)
DESIGN :
- GRID pattern with spacing 3 mm
- Tested Field Sizes: Circular - max. 2 cm
- Integrated Barometer and Thermometer
- Dimensions / Weight: 40x130x6 mm / 0.1kg
UNBEATABLE POWER / PRICE RATIO
|